- Self-consumption and feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
- Built-in Timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real time status display and control
- Custom-made firmware by ODM contract
- Parallel operation up to 6 units for KW and 10KW
MODEL
|
InfiniSolar 3 Phase 10KW
|
PHASE
|
3-phase /3-phase out
|
MAXIMUM PV INPUT POWER
|
14850 W
|
RATED OUTPUT POWER
|
10000 W
|
MAXIMUM CHARGING POWER
|
9600 W
|
GRID-TIE OPERATION
|
|
PV INPUT (DC)
|
|
Nominal DC Voltage / Maximum DC voltage
|
720 VDC / 900 VDC
|
Start-up Voltage / Initial Feeling Voltage
|
320 VDC / 350 VDC
|
MPP voltage Range
|
400 VDC~800 VDC
|
Number of mpp Trackers/ Maximum Input current
|
2/ 2 x 18.6A |
GRID-TIE OPERATION
|
|
PV INPUT (DC)
|
|
Nominal DC Voltage / Maximum DC voltage
|
720 VDC/ 900 VDC
|
Start-up voltage / Initial feeding voltage
|
320 VDC / 350 |
MPP voltage Range
|
400 VDC - 800 VDC |
Number of MPP tracker / Maximum Input current
|
2/ 2 x 18.6A |
GRID OUTPUT (AC)
|
|
Nominal Output Voltage
|
230 VAC (P.N)/400 VAC (P.P) |
Output Voltage Range
|
184 - 265 VAC* per phase
|
Nominal output Current
|
14.5A per phase |
Power Factor
|
>0.99
|
EFFICIENCY
|
|
Maximum Conversion Efficiency (DC/AC)
|
96%
|
European Efficiency @ Vnominal
|
95%
|
OFF-GRID OPERATION
|
|
AC INPUT
|
|
AC Start-up Voltage / Auto Restart
|
120 - 140 VAC per phase/ 180 VAC per phase
|
Acceptable input Voltage Range
|
170 - 280 VAC
|
Maximum AC Input Current
|
40 A
|
PV INPUT (DC)
|
|
Maximum DC Voltage
|
900 VDC
|
MPP voltage Range
|
400 VDC ~800 VDC
|
Number of MPP Trackers / Maximum Input current
|
2/2 x 18.6A
|
BATTERY MODE OUTPUT (AC)
|
|
Nominal Output Voltage
|
230 VAC(P-N)/ 400 VAC(P.P) |
Output Waveform
|
Pure Sinewave
|
Efficiency (DC to AC)
|
91%
|
HYBRID OPERATION
|
|
PV INPUT (DC)
|
|
Nominal DC Voltage / Maximum DC voltage
|
720 VDC / 900 VDC
|
Start-up voltage / Initial feeding voltage
|
320 VDC / 350 VDC
|
MPP voltage Range
|
400 VDC~800 VDC
|
Number of MPP trackers / Maximum Input current
|
2/2 x 18.6A
|
GRID OUTPUT (AC)
|
|
Nominal Output Voltage
|
230 VAC(P-N)/ 400 VAC(P.P) |
Output Voltage Range
|
184 - 264.5 VAC* per phase
|
Nominal output Current
|
14.5A |
AC INPUT
|
|
AC Start-up voltage/ Auto restart Voltage
|
120 - 140 VAC per phase / 180 VAC per phase
|
Acceptable Input Voltage Range
|
170 - 280 VAC
|
Maximum AC Input Current
|
40 A
|
BATTERY MODE OUTPUT (AC)
|
|
Nominal Output Voltage
|
230 VAC(P-N)/ 400 VAC(P.P) |
Efficiency (DC to AC)
|
91%
|
BATTERY & CHARGER
|
|
Nominal DC Voltage
|
48 VDC
|
Maximum Charging current
|
Default 60 A, 10A - 200A (Adjustable)
|
GENERAL
|
|
PHYSICAL
|
|
Dimension, D x W x H (mm)
|
167.5 x 500 x 622
|
Net Weight (kgs)
|
45 |
INTERFACE
|
|
Communication Port
|
RS - 232/ USB
|
Intelligent slot
|
Optional SNMP, Modbus & AS-400 cards available
|
ENVIRONMENT
|
|
Humidity
|
0 '' 90% RH (Non-Condensing)
|
Operating Temperature
|
-10 to 55°C
|
Altitude
|
0 " 1000 m°°
|